Input
BTU/H
100,000
125,000
150,000
175,000
200,000
225,000
250,000
300,000
350,000
400,000
Conversion
Kit No.
261R06377
261R06377
261R06377
261R06377
261R06377
261R06377
261R06377
261R06377
261R06377
261R06377
Orifi ce
Size Nat.
#54
#54
#54
#54
#54
#54
#54
#54
#54
#54
Orifi ce
Quantity
4
5
6
7
8
9
10
12
14
16
12/06
Replacement
Valve
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Original Valve
(See Note)
VR8204A2001
VR8204A2001
VR8204A2001
VR8204A2001
VR8204A2001
VR8304M4002
VR8304M4002
VR8304M4002
VR8304M4002
VR8304M4002
J30-06377
INSTALLATION INSTRUCTIONS
NATURAL to L.P. GAS CONVERSION KIT
For 100,000-400,000 BTU/HR
Spark Ignition Unit Heaters & Duct Furnaces
with Honeywell S8600F Ignition Modules
Kit Contents
Main Burner Orifi ces (16)*
503-00054-016
Pilot Burner Orifi ce
BBR 11
J36-00785-014
Honeywell Gas Valve Con-
version Kit
HW# 393691
J29-04864-001
Honeywell Ignition Module
HW# S8600M1013/3001
J28-02722
Conversion Plate
J17-02755
“Notice of Conversion” Label
J17-02754
L.P. Gas High Altitude Orifi ce Chart for The United States
L.P. Gas High Altitude Orifi ce Chart for Canada
Elevation (ft.)
0-1,999 2,000-2,999 3,000-3,999 4,000-4,999 5,000-5,999 6,000-6,999 7,000-7,999 8,000-8,999 9,000-9,999 10,000-10,999
Orifi ce Size 54 54 55 55 55 55 55 56 56 56
Elevation (ft.)
0-1,999 2,000-4,500 4,501-5,500 5,501-6,500 6,501-7,500 7,501-8,500 8,501-9,500 9,501-10,500 10,501-11,500
Orifi ce Size 54 55 55 55
55 56 56 56 56
Note: Appliances manufactured prior to
May 1, 2001 may have a VR8304M3103 or
a 36C68-434 gas valve. This kit applies to
the VR8304M3103 valve. Kit No. 261R06378
must be used to convert an appliance with
the 36C68 valve.
*This conversion kit includes (16) main burner
orifi ces. See the quantity of orifi ces required per
input/heater size shown in the table above. Use
only the quantity required.
This conversion kit shall be installed by a qualifi ed service agency
in accordance with the manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, explosion or production of carbon
monoxide may result causing property damage, personal injury or loss of life.
The qualifi ed service agency performing this work assumes responsibility for the
proper conversion of this appliance with this kit.
AVERTISSEMENT Cette trousse de conversion ne doit être installée que par
le représentant d'un organisme qualifi é et conformément aux instructions du
fabricant et à tous les codes et exigences pertinenetes de l'autorité compétente.
Quiconque ne respecte pas à la lettre les instructions du présent guide risque
de provoquer un incendie, une explosion ou des fuites de monoxyde de car-
bone entraînant des dommages matériels, des lésions corporelles ou la perte
de vies humaines. L'organisme qualifi é qui effectue les travaux est responsable
de la conversion correcte de cet appareil à l'aide de cette trousse.
(1 Foot = 0.305 m)
Page view 0
1 2 3 4

Summary of Contents

Page 1 - J30-06377

InputBTU/H100,000125,000150,000175,000200,000225,000250,000300,000350,000400,000ConversionKit No.261R06377261R06377261R06377261R06377261R06377261R0637

Page 2

READ ALL INSTRUCTIONS COMPLETELY BEFORE BEGINNING ANY WORK!1. All work must be performed by a fully qualifi ed, experienced, and trained service techn

Page 3

7. Reinstall the pilot assembly. Reconnect the pilot gas tubing to the gas valve.8. Install the fi rst main burner adjacent to the pilot assembly (see

Page 4 - Figure 2

CARRY-OVERToo Little AirYellow TippingYellowPILOT BURNERPILOT ORIFICETUBING FITTINGNormal FlameBlue FlameFigure 4Gas Pressureor ExcessiveToo Much AirL

Comments to this Manuals

No comments